€ 1,570.00
The Autoflame MM10006/250 is a temperature detector designed for boiler, HVAC and burner monitoring applications, capable of measuring ambient or fluid temperatures from 0 to 400 °C. With a 250 mm probe length, stainless steel housing, PT1000 resistance element and IP65 protection rating, this detector provides reliable load or exhaust temperature monitoring in industrial combustion systems.
In stock
Overview
The Autoflame MM10006/250 is a temperature detector designed for boiler, HVAC and burner monitoring applications, capable of measuring ambient or fluid temperatures from 0 to 400 °C. With a 250 mm probe length, stainless steel housing, PT1000 resistance element and IP65 protection rating, this detector provides reliable load or exhaust temperature monitoring in industrial combustion systems.
Key Features
Measurement range: 0 to 400 °C
Probe length: 250 mm
Stainless steel probe and housing
PT1000 two-wire resistance element
IP65 and NEMA 4 rated
Suitable for use as load sensor, exhaust temperature shutdown sensor, or fluid temperature monitor in burner control system
Compact installation via ½” BSP connection thread
Main Benefits
Allows accurate temperature monitoring in harsh combustion or boiler environments
Durable stainless steel construction for long life and minimal maintenance
Standardised sensor for integration with burner control units and systems
Helps protect equipment by enabling temperature-based safety/shutdown thresholds
Technical Highlights
Part number: MM10006/250
Measurement range: 0-400 °C
Weight: approx. 0.45 kg
Probe length: 250 mm
Housing thread: ½″ BSP (or ½″ NPT variant available)
Protection class: IP65, NEMA 4
Ambient temperature for sensor electronics: up to 85 °C (220 °F)
Response time: 0.1 s typical
Installation & Safety Notes
Install by qualified personnel according to applicable electrical and combustion safety standards.
Ensure sensor is mounted in full contact with the medium being measured (fluid or exhaust gas) for accurate readings.
Use correct mounting torque and ensure sealing at threaded connection.
Avoid placing sensor in unsupported or low-flow areas where readings may be delayed or inaccurate.
Periodically inspect for insulation damage, corrosion or mechanical stress.
Applications
Exhaust temperature monitoring and shutdown in industrial burners
Boiler load temperature detection for combustion control
HVAC process temperature measurement in heating systems
Retrofitting into existing burner control systems using the MM sensor platform
| Weight | 0.5 kg |
|---|---|